North Waitakere Sewer

  

CDS Installed 3.5km of 400mm to 630mm pipeline installed at flat grades (down to 0.13%) through varying ground conditions including rock. An unusually large number of unmarked service conflicts with proposed alignments were successfully mitigated by the engineering capabilities of the project team.

  •  Like
  •  
  •  Tweet
  •  
  •  +1
  •  
  •  Pin it
  •  

RELATED PROJECTS

  • Manukau North Local Wastewater Network Upgrade

    This Watercare contract involved the upgrading of the wastewater network in 9 separate areas in the Howick and Pakuranga area in Auckland.

  • Lawsons Creek Branch Sewer Early Works

    The Lawsons Creek Branch Sewer Early Works were a critical installation done for Watercare Services Limited and their main contractor Pipeline & Civil Limited

  • Hastings Pde Stormwater Renewals

    This project involved installing 100m of 250mm PE pipe inside an existing reinforced concrete pipe and PE pipe using pipe bursting and slip lining technologies

  • Tauranga Te Awanui Drive Watermain Slip Lining

    CDS installed 680m of 315mm PE pipe via slip lining inside and existing 350mm PVC pipe. This pipe was installed using our DitchWitch® JT4020 drill, in 2 separate drill shots

  • Mellons Bay Branch Sewer

    CDS were contracted to install a single length 115m of 350mmØ gravity sewer to a grade of 0.3%.

  • Franklin Road Stormwater Upgrade

    CDS was contracted to install 400m of 400mm Ø and 450mm Ø PE pipework by pipebursting the existing 300mm diameter stormwater pipe running under Franklin Road

ABOUT

CDS’s technical expertise in directional drilling has grown year on year and is now a leader in the industry with extensive local knowledge that is critical to success. CDS has never been afraid to step up to the mark for the more technical, high risk, drilling installations and prides itself at never walking away from a project until the pipe is underground and our client happy.

SERVICES

  • LOW GRADE INSTALLATIONS
  • HYDRO EXCAVATION
  • PIPE BURSTING / SLIP LINING
  • DRILLING IN ROCK
  • CURVED ALIGNMENTS
  • DIRECTIONAL DRILLING

GET IN TOUCH

© 2017 - 2019 CDS New Zealand Ltd
Site designed & developed by STUDIOELEVEN
